hardware:asus_rs500a-e11-rs12u
Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| hardware:asus_rs500a-e11-rs12u [2026/02/02 20:34] – created thum | hardware:asus_rs500a-e11-rs12u [2026/04/22 11:55] (current) – thum | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | <note tip> | + | ====== ASUS RS500A-E11-RS12U ====== |
| - | This page will be updated and expanded soon. | + | |
| - | </ | + | |
| - | + | ||
| - | ====== ASUS RS500A-E11-RS12U | + | |
| ===== General Information ===== | ===== General Information ===== | ||
| - | The ASUS RS500A-E11-RS12U is an AMD EPYC 7003 (Milan) 1U single-socket server that supports up to 16x DIMM, 12x NVMe, 3x PCIe 4.0 slots, 1x OCP 3.0, 2x M.2 and ASUS ASMB10-iKVM and in use for the # vikings | + | The ASUS RS500A-E11-RS12U is an AMD EPYC 7003 (Milan) 1U single-socket server |
| + | |||
| + | ===== Rear Panel Features ===== | ||
| + | |||
| + | < | ||
| + | PCIe Gen4 x16,slots, LP (x16 link) | ||
| + | ▲ | ||
| + | │PCIe Gen4 x16 slot, LP (x8 link) | ||
| + | │ ▲ | ||
| + | └┐ | ||
| + | | ||
| + | ┌────┬────┬┼───────────┼───────────────────────┼─────┐ | ||
| + | │ │ │├─────────┐ ├─────────┐ | ||
| + | │ │ │└─────────┘ └─────────┘ | ||
| + | │ PSU│ PSU│ | ||
| + | │ │ │ ┌─┐ ├──┘ | ||
| + | │ │ ┌──┼─┴─┘ ├──┐ | ||
| + | │ │ │ │ | ||
| + | └────┴─┼──┴─────┼─────▼────┼───┼───┼─────────┼───────┘ | ||
| + | | ||
| + | QCode LED 2x USB3.2 Gen1 │ LAN1 ▼ | ||
| + | │ 1Gbe LAN2 | ||
| + | BMC ◄────┘ | ||
| + | </ | ||
| + | |||
| + | ===== Issues ===== | ||
| + | |||
| + | ==== No PCIe Bifurcation Support ==== | ||
| + | |||
| + | The mainboard does not support PCIe bifurcation. | ||
| + | |||
| + | === Example Intel E810-CQDA2 === | ||
| + | |||
| + | The card has two internal controllers, | ||
| + | aggregate bandwidth is limited to approx. 125 Gbps on a PCIe 4.0 x16 slot effective throughput, meaning both ports cannot simultaneously run at full 100 Gbps — only one port at a time can reach line rate. | ||
| + | |||
| + | === Example Intel E810-XXVDA4 === | ||
| + | |||
| + | Contrary to the E810-CQDA2 the Intel E810-XXVDA4 has **one** internal controller, which receives adequate PCIe bandwidth without requiring bifurcation. | ||
| + | |||
| + | ==== Low-Profile Slot Port Obstruction Finding ==== | ||
| + | |||
| + | When using 4-port network cards in one of the low-profile slots, the server chassis obscures one of the ports by about 0.5 mm. Inserting a GBIC (or SFP transceiver) is possible with some force, but subsequent removal is very difficult or impossible. | ||
| + | |||
| + | * Potential Fixes | ||
| + | * When purchasing network cards with 4 slots, use the OCP3.0 or full-height port if possible | ||
| + | * For stuck GBICs, **gently** wiggle while pulling or use a flathead screwdriver for leverage without forcing, to prevent port damage | ||
| + | * //If you're feeling brave, you can use a Dremel tool to manipulate the areas. | ||
| + | |||
| + | |||
| + | ===== See also ===== | ||
| + | |||
| + | [[hardware: | ||
| + | |||
| + | {{tag> | ||
hardware/asus_rs500a-e11-rs12u.1770064457.txt.gz · Last modified: by thum